Juliet Balcony Components
-
From: £5.22
End Cap Flat used for the construction of our Ariel Juliet Balcony.
Our range of connectors, allows you to join tube to tube and tube to wall at any conceivable angle. If you are installing in tight corners or on uneven surfaces our products provide a practical solution to every challenge. All of our connectors are designed to fit perfectly with our tube.
-
From: £10.67
We stock a range of brackets that are designed to be inserted straight into the upright. These are for either 42.4 or 48.3 uprights. Should your handrail design require you to turn a corner, we stock brackets with 90 degree saddles. We stock handrail adapters for either 42.4 or 48.3 upright. They can accommodate either 42.4 or 48.3 mil tube. The handrail adapters are attached to the tube by gluing
-
£51.35
Our range of connectors, allows you to join tube to tube and tube to wall at any conceivable angle. If you are installing in tight corners or on uneven surfaces our products provide a practical solution to every challenge. All of our connectors are designed to fit perfectly with our tube.
PLEASE NOTE: Measurement is taken from outside of profile to outside of profile.
Skyforce Top Mount according Test BS 6180 (0,74 kN/m)Tested to Aluminium
GLASS WIDTH UP TO |
GLASS THICKNESS (tempered glass) |
GLASS HEIGHT |
1000mm |
12.76mm |
300mm – 1100mm |
1700mm |
16.76mm |
300mm – 1100mm |
3000mm |
21.52mm |
500mm – 1100mm |
(According test BS 6180)
Tested on the basis that the minimum thickness of the aluminium frame is 1.4mm.
FIXING TO PVC FRAME
SkyForce Top Mount Tested to Plastic According to the German Standard ETB Directive
GLASS WIDTH UP TO |
GLASS THICKNESS (tempered glass) |
GLASS HEIGHT |
1600mm |
12.76mm |
700mm-1200mm |
2100mm |
16.76mm (17.52) |
900mm-1200mm |
2600mm |
21.52mm |
800mm-1100mm |
Tested on the basis that the metal insert in the frame is a minimum of 1.5mm in thickness. I attach a copy of the test report which is in German but which I think we can include anyway.
FIXING TO STEEL OR CONCRETE
Skyforce is fully tested at a height of 1.1m up to a width of 3m when fixed to steel or concrete.
Glass |
H = Glass Height |
L = Glass Length |
Working Line Load |
6.62 |
min. 300mm - max. 1100mm |
max. 1100mm |
3.0 kN/m |
6.62 |
min. 500mm - max. 1100mm |
max. 1100mm |
3.0 kN/m |
|
|
|
|
8.84 |
min. 300mm < 500mm |
max. 1100mm |
3.0 kN/m |
8.84 |
min. 500mm - max. 1100mm |
max. 1100mm |
3.0 kN/m |
8.84 |
min. 600mm - max. 1100mm |
max. 1700mm |
1.5 kN/m |
8.84 |
min. 300mm < 600mm |
max. 1700mm |
0.74 kN/m |
|
|
|
|
10.10.4 |
min. 300mm < 500mm |
max. 500mm |
3.0 kN/m |
10.10.4 |
min. 500mm - max. 1100mm |
max. 1100mm |
3.0 kN/m |
10.10.4 |
1100mm |
max. 3000mm |
0.74 kN/m |
10.10.4 |
min. 300mm < 1100mm |
max. 3000mm |
0.36 kN/m |
FIXED TO TIMBER OR STONE/BRICKWORK
No test data available.
For more comprehensive test data,
click here