Our round end fittings and slotted tube are one of our most popular applications when installing a Juliet Balcony. The fixings are installed on the walls besides the opening. They are supplied in grade 316 stainless steel with the cap rail and the gasket. The end fittings are designed to accommodate a 42mm slotted tube. We can cut the slotted tube to any length that you require to fit exactly the façade of your Juliet balcony.
-
£52.80
Our round end fittings and slotted tube are one of our most popular applications when installing a Juliet Balcony. The fixings are installed on the walls besides the opening. They are supplied in grade 316 stainless steel with the cap rail and the gasket. The end fittings are designed to accommodate a 42mm slotted tube. We can cut the slotted tube to any length that you require to fit exactly the façade of your Juliet balcony.
PLEASE NOTE: Measurement is taken from outside of profile to outside of profile.
Skyforce Top Mount according Test BS 6180 (0,74 kN/m)Tested to Aluminium
GLASS WIDTH UP TO |
GLASS THICKNESS (tempered glass) |
GLASS HEIGHT |
1000mm |
12.76mm |
300mm – 1100mm |
1700mm |
16.76mm |
300mm – 1100mm |
3000mm |
21.52mm |
500mm – 1100mm |
(According test BS 6180)
Tested on the basis that the minimum thickness of the aluminium frame is 1.4mm.
FIXING TO PVC FRAME
SkyForce Top Mount Tested to Plastic According to the German Standard ETB Directive
GLASS WIDTH UP TO |
GLASS THICKNESS (tempered glass) |
GLASS HEIGHT |
1600mm |
12.76mm |
700mm-1200mm |
2100mm |
16.76mm (17.52) |
900mm-1200mm |
2600mm |
21.52mm |
800mm-1100mm |
Tested on the basis that the metal insert in the frame is a minimum of 1.5mm in thickness. I attach a copy of the test report which is in German but which I think we can include anyway.
FIXING TO STEEL OR CONCRETE
Skyforce is fully tested at a height of 1.1m up to a width of 3m when fixed to steel or concrete.
Glass |
H = Glass Height |
L = Glass Length |
Working Line Load |
6.62 |
min. 300mm - max. 1100mm |
max. 1100mm |
3.0 kN/m |
6.62 |
min. 500mm - max. 1100mm |
max. 1100mm |
3.0 kN/m |
|
|
|
|
8.84 |
min. 300mm < 500mm |
max. 1100mm |
3.0 kN/m |
8.84 |
min. 500mm - max. 1100mm |
max. 1100mm |
3.0 kN/m |
8.84 |
min. 600mm - max. 1100mm |
max. 1700mm |
1.5 kN/m |
8.84 |
min. 300mm < 600mm |
max. 1700mm |
0.74 kN/m |
|
|
|
|
10.10.4 |
min. 300mm < 500mm |
max. 500mm |
3.0 kN/m |
10.10.4 |
min. 500mm - max. 1100mm |
max. 1100mm |
3.0 kN/m |
10.10.4 |
1100mm |
max. 3000mm |
0.74 kN/m |
10.10.4 |
min. 300mm < 1100mm |
max. 3000mm |
0.36 kN/m |
FIXED TO TIMBER OR STONE/BRICKWORK
No test data available.
For more comprehensive test data,
click here