Loading...

Tag Archives: Do I Need Planning Permission For A Juliet Balcony?

Juliet balcony in Dumfries Scotland

Juliet Balcony in Dumfries Scotland

Juliet Balcony in Dumfries Scotland There are many features you can have in your loft conversion, but none more beautiful so than a Juliet balcony. The epitome of romance, the Juliet balcony gains its name from the timeless classic of Romeo and Juliet. In which Juliet would speak to Romeo from her balcony. Whilst we

Juliet Balcony

Do I Need Planning Permission For A Juliet Balcony?

We are often asked, “Do I need planning permission for a Juliet balcony?” The good news is that the vast majority of cases you Don’t. Juliet balconies are classed as Permitted Developments and therefore will not need planning permission. One of the main benefits of a Juliet balcony is that you can replace your windows

PLEASE NOTE: Measurement is taken from outside of profile to outside of profile.

Skyforce Top Mount according Test BS 6180 (0,74 kN/m)Tested to Aluminium
GLASS WIDTH UP TO GLASS THICKNESS (tempered glass) GLASS HEIGHT
1000mm 12.76mm 300mm – 1100mm
1700mm 16.76mm 300mm – 1100mm
3000mm 21.52mm 500mm – 1100mm
(According test BS 6180) Tested on the basis that the minimum thickness of the aluminium frame is 1.4mm.   FIXING TO PVC FRAME SkyForce Top Mount Tested to Plastic According to the German Standard ETB Directive
GLASS WIDTH UP TO GLASS THICKNESS (tempered glass) GLASS HEIGHT
1600mm 12.76mm 700mm-1200mm
2100mm 16.76mm (17.52) 900mm-1200mm
2600mm 21.52mm 800mm-1100mm
Tested on the basis that the metal insert in the frame is a minimum of 1.5mm in thickness. I attach a copy of the test report which is in German but which I think we can include anyway.   FIXING TO STEEL OR CONCRETE Skyforce is fully tested at a height of 1.1m up to a width of 3m when fixed to steel or concrete.
Glass H = Glass Height L = Glass Length Working Line Load
6.62 min. 300mm - max. 1100mm max. 1100mm 3.0 kN/m
6.62 min. 500mm - max. 1100mm max. 1100mm 3.0 kN/m
8.84 min. 300mm < 500mm max. 1100mm 3.0 kN/m
8.84 min. 500mm - max. 1100mm max. 1100mm 3.0 kN/m
8.84 min. 600mm - max. 1100mm max. 1700mm 1.5 kN/m
8.84 min. 300mm < 600mm max. 1700mm 0.74 kN/m
10.10.4 min. 300mm < 500mm max. 500mm 3.0 kN/m
10.10.4 min. 500mm - max. 1100mm max. 1100mm 3.0 kN/m
10.10.4 1100mm max. 3000mm 0.74 kN/m
10.10.4 min. 300mm < 1100mm max. 3000mm 0.36 kN/m
FIXED TO TIMBER OR STONE/BRICKWORK   No test data available.   For more comprehensive test data, click here
We use cookies to improve your experience on our website. By browsing this website, you agree to our use of cookies.